Test and tag register template: columns that pass an audit

Last reviewed 29 October 2026 · Sources linked below · Written by Jay at Andwat Co, an Australian boilermaker/fabricator (Cert III Engineering, 12+ years in the trade). About

As an Amazon Associate I earn from qualifying purchases.

What to put in an Australian test and tag register: asset ID, test date, next due, outcome, tester, intervals by environment, and a printable row layout that links to ready spreadsheets.

Auditors and principal contractors ask for a test and tag register, not a box of loose tags. Our test and tag guide covers AS/NZS 3760 intervals. This page is the register template: the columns that stop overdue leads staying on site.

The short answer

Printable register row (copy into a spreadsheet)

Asset IDDescriptionLocationClassTest dateNext dueResultTesterNotes
LEAD-01415 A extension 20 mUte kerbsideI12/09/202612/12/2026PassJ. AndrewsConstruction 3-month
GRN-0039" angle grinderWorkshop benchII01/07/202601/01/2027PassExternalFactory 6-month
RCD-001Portable RCDSite box—12/09/202612/10/2026PassJ. AndrewsPush-button daily + formal

Worked example – mobile welder kit

Twelve leads and tools on the ute. Construction environment → 3-month interval for Class I equipment. Register sorted by next due. Anything inside 14 days of due gets tested on the next quiet Friday. Failed grinder lead quarantined in a red tub, not left coiled with the good leads.

Useful gear (affiliate): digital multimeter for basic continuity checks by a competent person, and a LED torch when tagging boards in dark switch rooms. Testing itself must be done by a competent person with the right equipment.

Quick answers

What interval should my register use?

Follow AS/NZS 3760 guidance for the environment and equipment class, plus manufacturer instructions. Construction sites are typically shorter than offices.

Can I keep tags without a register?

Tags help on the tool. The register is what proves history, next due and who tested it.

Who can test and tag?

A competent person. Some states have extra licensing rules for certain work. Check your state regulator.

Should plant inspections share the same due date?

No. Plant, lifting gear and electrical test-and-tag are different systems. One workbook with separate due columns is fine.